running epc.exe
Thu, 12 Jun 2008 05:18:02 -0700
epc.exe works when running it to change user and password but only when the
orginal user that installed the TEC connector for OPS MGR runs it. Has anyone
else had this problem? ...
|
forwarding state changes with "Engyro"-SCOM to OVO connector
Thu, 12 Jun 2008 05:18:00 -0700
Hi,
is it possible to forward state changes from SCOM to OVO somehow. With
subscriptions I only see the possibility to forward alerts. Do I really have
to write overrites for all the rules of the sealed MPs. These thoughts are
driving me nuts.
Please tell me how I can get out of that. (maybe with the rol ...
|
Connector for FrontRange ITSM
Tue, 3 Jun 2008 15:21:01 -0700
I am working on generating auto ticket from OpsMgr2007 to ITSM (FrontRange)
product. I have the XML file with all fields configure for the ticketing
system. Question I have is how would i plug that into OpsMgr so that it would
generate a ticket when the issue is critical? Please help. ...
|
Optional field - "Monitoring Object Display Name" not sent
Tue, 3 Jun 2008 09:19:00 -0700
Via EngryoTEConfig, we enable a number of optional fields to be sent to TEC.
We saw the content of most optional fields received successfully on TEC side.
However, the monitoring obj display name is not one of the fields..
The field is important as we need to display the agent hostname on TEC in
case the a ...
|
HP MOM TO OVO Connector 1.0 - System.NullReferenceException (MOM 2
Thu, 29 May 2008 05:14:01 -0700
searching for a workarround about the following
A)
Since a while all our connectors in all environements brings up this
eventlog entries within the default polling intervall (30s)and EventID 9999:
PCBase.ProcessAlerts: Call to send EM events failed:
System.NullReferenceException: Object reference not set ...
|
Field <OptPriority>true</OptPriority> not shown in TEC epc.Priorit
Tue, 27 May 2008 06:27:01 -0700
Hi All,
At the moment I'm testing the Scom2tec connector , but I have some problems
that the epc.Priority attribute in TEC isn't filled , even if scom sends it
in the connector which is shown ( in debugmode) in the epc.log file
2008-05-22 13:37:43,823 DEBUG tor.EMInterface LogEMEvent - PC.SendToEM:
Pr ...
|
Engyro 64-bit considerations
Mon, 26 May 2008 12:46:04 -0700
Hi,
There had been a post here on this issue but it has disappeared.
It was a great help for me on installing Engyro Product Connector on 64-bit
RMS server, so I try to summarize it.
Before installing the web config component the following preparation is
needed:
1. Copy cscript.exe from c:\windows\syswow64 ...
|
|
|
Engyro OVE Connector Console problem
Sun, 25 May 2008 10:28:01 -0700
Hi,
I have installed Engyro HPOVO Connector in a test environment. SCOM 2007 is
installed as a single server architecture on a x64-bit Windows.
I have installed the web console according to the installation guide and the
posts here on x64-bit installation (except the 4th point, I left ASP.NET on
64-bit mod ...
|
Error decoding password
Sun, 25 May 2008 00:25:00 -0700
Hi,
I have installed the Engyro OM2007 to HP OVO Product Connector and the
service is successfully started but i can't forward the events to the ovo
server showing error ID 2059 "2008-05-25 10:14:22,107 Error decoding
password: Key not valid for use in specified state."
Although i am sure of the password ...
|
Engyro OVO config
Fri, 23 May 2008 07:46:03 -0700
I installed the Engyro OVO Connector.
When I go the configuration site I get the message "Action canceled"
It seems to work but I cannot change the settings!
Does anyone have any clues how to solve this?
...
|